Fortress Stabilization Case Study
Case Studies
Residential Block Wall Shear Repair and Reinforcement
Fortress Stabilization Case Study The Fortress Story Reinforcing Sheared and Bowing Block Walls with InvisiBeam® for Lasting Structural Stability The Challenge During a full renovation of a hillside home, contractors…
Foundation Reinforcement for Rebar Pop Repair in California
Fortress Stabilization Case Study The Fortress Story Saving a California Home from Costly Foundation Replacement with Fortress Composite Reinforcement The Challenge A California homeowner discovered reinforcement steel was popping out…
Factory-to-Hotel Conversion Reinforcement with Fortress ReGrid®
Fortress Stabilization Case Study The Fortress Story Reinforcing Historic Industrial Floors for Modern Hotel Use with Fortress ReGrid® The Challenge A 1926 industrial building undergoing conversion into a hotel required…
ReGrid Surface Mount Straps Overhead Installation
Fortress Stabilization Case Study The Fortress Story Repairing Corroded Span-Crete Box Planks with Fortress ReGrid® in Wisconsin The Challenge A Wisconsin home with Span-Crete box planking over the crawlspace was…
I-95 Miami Skate Park Bridge Repair
Fortress Stabilization Case Study The Fortress Story Strengthening I-95 Viaduct Beams with Carbon Fiber U-Wraps for Miami Skate Park Lighting The Challenge As part of a community project, the Miami…
Cold Pour Basement Wall Repair with InvisiBeam®
Fortress Stabilization Case Study The Fortress Story This non-reinforced, cold pour foundation wall showed significant cracking. The cracking worsened over the years leading to a structural deficiency that required…
InvisiBeam® Repair Saves 1930s Block Foundation from Full Replacement
Fortress Stabilization Case Study The Fortress Story Repairing Sheared Block Foundation Walls with InvisiBeam® to Avoid Replacement The Challenge A home built in the 1930s with block foundation walls was…
Fortress Carbon Corner Repair for Failing Foundation Wall Corners
Fortress Stabilization Case Study The Fortress Story Project Scope: 14 course high un-reinforced 12″ cement block basement wall failure. The corner of the inside basement/garage wall had broken and pulled…
Reinforcing Bowed Brick Foundation Walls with Fortress Carbon/Kevlar Straps
Fortress Stabilization Case Study The Fortress Story Stabilizing Bowed Brick Foundation Walls with Fortress Carbon/Kevlar® Straps The Challenge An older home was experiencing bowing brick foundation walls, threatening the structural…
InvisiBeam® Installation for Glazed Tile Foundation Wall Stabilization
Fortress Stabilization Case Study The Fortress Story Stabilizing Glazed Tile Foundation Walls with Fortress InvisiBeam® Straps The Challenge A glazed tile foundation wall was experiencing horizontal cracking and structural instability.…